TSL1401CL
128 ?1 LINEAR SENSOR ARRAY WITH HOLD
TAOS136  JULY 2011
9
The LUMENOLOGY r Company
r
r
Copyright E 2011, TAOS Inc.
www.taosinc.com
APPLICATION INFORMATION
The minimum integration time can be calculated from the equation:
  T
int(min)
+
1
maximum clock frequency
 (n * 18)pixels ) 20ms
where:
n    is the number of pixels
In the case of the TSL1401CL with the maximum clock frequency of 8 MHz, the minimum integration time would
be:
  T
int(min)
+ 0.125ms   (128 * 18) ) 20ms + 33.75ms
It is good practice on initial power up to run the clock (n+1) times after the first SI pulse to clock out indeterminate
data from power up. After that, the SI pulse is valid from the time following (n+1) clocks. The output will go into
a high-impedance state after the n+1 high clock edge. It is good practice to leave the clock in a low state when
inactive because the SI pulse required to start a new cycle is a low-to-high transition.
The integration time chosen is valid as long as it falls in the range between the minimum and maximum limits
for integration time. If the amount of light incident on the array during a given integration period produces a
saturated output (Max Voltage output), then the data is not accurate. If this occurs, the integration period should
be reduced until the analog output voltage for each pixel falls below the saturation level. The goal of reducing
the period of time the light sampling window is active is to lower the output voltage level to prevent saturation.
However, the integration time must still be greater than or equal to the minimum integration period.
If the light intensity produces an output below desired signal levels, the output voltage level can be increased
by increasing the integration period provided that the maximum integration time is not exceeded. The maximum
integration time is limited by the length of time the integrating capacitors on the pixels can hold their accumulated
charge. The maximum integration time should not exceed 100 ms for accurate measurements.
It should be noted that the data from the light sampled during one integration period is made available on the
analog output during the next integration period and is clocked out sequentially at a rate of one pixel per clock
period. In other words, at any given time, two groups of data are being handled by the linear array: the previous
measured light data is clocked out as the next light sample is being integrated.
Although the linear array is capable of running over a wide range of operating frequencies up to a maximum
of 8 MHz, the speed of the A/D converter used in the application is likely to be the limiter for the maximum clock
frequency. The voltage output is available for the whole period of the clock, so the setup and hold times required
for the analog-to-digital conversion must be less than the clock period.
相关PDF资料
TSL1401CS-LF IC OPTO SENSOR ARRAY CSP PCB MT
TSL1402R IC LINEAR SENSOR ARRAY 256X1
TSL1406RS IC LINEAR SENSOR ARRAY 768X1
TSL1410R IC LINEAR SENSOR ARRAY 1280X1
TSL1412S IC LINEAR SENSOR ARRAY 1536X1
TSL2014 IC LINEAR SENSOR ARRAY 896X1
TSL202R IC LINEAR SENSOR ARRAY 128X1
TSL208R IC LINEAR SENSOR ARRAY 512X1
相关代理商/技术参数
TSL1401CS 制造商:未知厂家 制造商全称:未知厂家 功能描述:128 1 LINEAR SENSOR ARRAY WITH HOLD
TSL1401CS-LF 功能描述:光频率和光电压 Linear Sensor Array 400dpi 128pix RoHS:否 制造商:ams 峰值波长:1000 nm 工作电源电压:5 V 最大工作温度:+ 85 C 最小工作温度:- 25 C 安装风格: 封装 / 箱体:
TSL1401R 功能描述:光频率和光电压 Linear Sensor Array 400dpi 128pix RoHS:否 制造商:ams 峰值波长:1000 nm 工作电源电压:5 V 最大工作温度:+ 85 C 最小工作温度:- 25 C 安装风格: 封装 / 箱体:
TSL1401R-LF 功能描述:光频率和光电压 Linear Sensor Array 400dpi 128pix RoHS:否 制造商:ams 峰值波长:1000 nm 工作电源电压:5 V 最大工作温度:+ 85 C 最小工作温度:- 25 C 安装风格: 封装 / 箱体:
TSL1401USBEVM 功能描述:光学传感器开发工具 TSL1401 Eval Module with USB Interface RoHS:否 制造商:ams 工具用于评估: 接口类型: 最大工作温度:
TSL1402R 功能描述:光学开关,专业型 Linear Sensor 400 DPI RoHS:否 制造商:ams 感应方式: 安装风格:Through Hole 封装:Tube
TSL1406 制造商:未知厂家 制造商全称:未知厂家 功能描述:768 X 1 LINEAR SENSOR ARRAY WITH HOLD
TSL1406R 功能描述:光学开关,专业型 400 DPI SENSOR (2) 384 PIXEL SECT. RoHS:否 制造商:ams 感应方式: 安装风格:Through Hole 封装:Tube